View Present
Image 1

You troubled with diffuser?


SEIKA Ecorator can Resolve!

View Present

Image 2

Long Life Time


No clogging, no sediment

View Present

Image 3

Smart Design


High oxygen absorption rate

View Present

Take Tour Take Tour

SEIKA Ecorator

New innovation air diffuser

The ecorator (air diffuser) has a powerful airlift effect that doubles the agitation in the tank. It is also practical for carrier flow systems.

The oxygen absorption rate is 30% higher compared to those of conventional cylindrical air diffusers.
The reduced exhaust pressure loss results in energy savings.

Download Catalog
App

Solution Air Diffuser


No Clogging (Even intermittent operation)
No maintenance!

No Aging Degradation
Keep initial dissolution efficiency!

High Mixing Power
No deposition of sludge in tank!

Principle

The flow along the venturi bumps and the direct flow together generate a stripping phenomenon (vortex) that creates fine air bubbles.

The fluid generates a stripping phenomenon and creates fine bubbles approx 300 μm in diameter.

Water that reaches the surface is sucked to the tank bottom by the down flow, which increases the DO value of the oxygen-rich part.

Product Lineup

Choose a model that fits your needs.

  • ECO-1000
  • Material SUS + PP
  • Air Blow 0.7-1.4 m3/min
  • Agitation 6-7 m2
  • Water depth 2 m +
  • Ecorator Jr.
  • Material PP
  • Air Blow 0.15-0.3 m3/min
  • Agitation 1-2 m2
  • Water depth 1 m +

1 Discuss Now!

PERMASALAHAN TEKNIS INSTALASI PENGOLAHAN AIR LIMBAH ... To solve the technical problems, it is very important to remove the sediment periodically and give aeration in the aerobic pond. ... Kabupaten Pandeglang telah beroperasi lebih Jawa Barat, Kalimantan Barat, Kalimantan Timur, dari 15 tahun. analisis risiko pada instalasi pengolahan air limbah Risiko lingkungan ini muncul jika Instalasi Pengolahan Air Limbah ... metode FailureMode and Effect Analysis (FMEA) dan Root Cause Analysis (RCA). ..... tangki aerasi dan menyebabkan air yang sudah ..... Surabaya : Jurusan Teknik Industri Institut Teknologi sepuluh Nopember Bapedalda Jawa Timur. evaluasi pengolahan air limbah dengan sistem extended aeration limbah yang mengacu pada Perda Provinsi Jawa Tengah No.5 Tahun 2012. Kemampuan IPAL kurang efisien menurunkan konsentrasi TSS dan BOD5, ... This is used to solve problems due to the previous system in order to ...

teknologi ipal yang effektif dan effisien Nugro Rahardjo : Redisain Instalasi Pengolahan Air Limbah... JAI Vol .6 ... To solve the problems, the WWTP must be redesigned and modifief by using a combination technique ..... bak aerasi dengan pompa sirkulasi lumpur. Jawa  Studi Kasus IPAL Pabrik Minyak Kelapa Sawit PT. ... it is very important to remove the sediment periodically and give aeration in the aerobic pond. ... Riau, Jambi, Bengkulu, Sumatera Selatan, Lampung, Banten, Jawa Barat, Kalimantan Barat, .. identifikasi masalah ipal domestik gedung perkantoran ... Kata kunci : identifikasi masalah, ipal domestik, pengolahan lanjut. Identifikasi ... In general, the main problem of domestic wastewater treatment plant (WWTP) for office buildings in. Jakarta is the .... ditanam di dasar bak aerasi, karena debit air. Jawa

Implementasi Instalasi Pengolahan Air Limbah (IPAL) - Journal | Unair Implementasi Instalasi Pengolahan Air Limbah (IPAL) Domestik Komunal: ... experiencing a number of problems. Keywords: ... Provinsi Jawa Timur, akses sanitasi layak sebesar 62,9% ..... perhatikan aerasi, pembersihan endapan lumpur  perencanaan instalasi pengolahan air limbah (ipal ... - teknik pengairan Kata Kunci: IPAL, kualitas air, limbah cair, penyamakan kulit, baku mutu,. ABSTRAK ... as a sollution for liquid waste problem of leather tanning process. The first step of the .... Kabupaten Magetan Provinsi Jawa Timur. Gambar. 1. ... bak aerasi. Perencanaan Instalasi Pengolahan Air Limbah (IPAL) mobil belum memiliki IPAL untuk mengolah limbah yang dihasilkan. Sehingga ... baku mutu lingkungan sesuai dengan Peraturan Gubernur Jawa. Timur Nomor 72 .... Panjang aerobik biofilter = 1 m (termasuk 2 tempat aerasi). Lebar bangunan. = 0,4 m. Panjang .... VIII, Issue I, June 2012, Page 61 – 70. [5] Maharani, R. M. 